In some cases there may be a need to to re-image your VidyoRoom.

Please take note of the settings including the portal address, username, and password before re-imaging.

 

HD40A/B HD100D HD230 HD600 Reimage Procedures:

  1. Please connect a USB keyboard to room system and reboot unit.
  2. As the unit is booting, on a keyboard, hold shift and tap the r key
  3. Continue until the recovery console appears
  4. Please run option 3 to delete settings

HD50,100,110,220 Rev A/B/C HD50/100 Prod 4 Reimage Procedures:

  1. Please connect a USB keyboard to room system and reboot unit.
  2. Hit F9 when you see " …0" on the top left (on boot-up).
  3. This will bring you to the recovery menu.
  4. Choose option 2 to restore the image.
Was this article helpful?
0 out of 0 found this helpful

2 Comments

Follow
  • 0
    Avatar
    GreenMeetings AB

    Same for HD40C.

    /J

  • 0
    Avatar
    Diego Carrillo

    For HD3 Shift + z key should work to enter into recovery menu