Partners Blog Contacts

The information in this article applies to the following products:

  • VidyoRoom™ HD-2
  • VidyoRoom HD-3
  • VidyoRoom HD-40 Revision A
  • VidyoRoom HD-40 Revision B
  • VidyoRoom HD-40 Revision C
  • VidyoRoom HD-100 Revision D
  • VidyoRoom HD-230 Revision A
  • VidyoRoom HD-230 Revision B
  • VidyoPanorama™ 600
  • VidyoRoom SE

What's New in This Release

Here's what's new in this release:

  • Introduction of the VidyoRemote™ 3 for Android™
    • The VidyoRemote 3 for Android application delivers pre-conference and in-conference control features for VidyoRoom and VidyoPanorama 600 systems. The VidyoRemote 3 app offers the usability benefits of a touch-screen control interface, with no need to purchase a dedicated controller. In addition, it provides users with an experience similar to the current VidyoRoom and VidyoPanorama 600 OnScreen UI. Here are some of the feature highlights:
      • Join and disconnect from conferences, and answer and reject incoming calls.
      • View the list of available local and remote content streams, and choose which one you want to display.
      • Select and configure which camera, microphone, speakers, and content capture device to use during your Vidyo calls. Pan, tilt, and zoom the camera, and adjust speaker and mic levels during calls.
      • View upcoming meetings and join those meetings with one-click (if calendar integration has been configured).
      • Use meeting control features, such as locking and unlocking the room, muting the audio and video, and disconnecting participants.
      • Record the conference.
      • Enable security features like setting an access codes and PIN-protecting a room.
    • The VidyoRemote 3 is available as a free download from the Google® Play Store.
  • Write Protection Mode enhancements
    • If you enable Write Protection mode and start the reboot process, you won’t be allowed to press the button again. This ensures that the reboot process fully and successfully completes.
    • When Write Protection Mode is enabled, you cannot delete log files nor can you upload new image, installer, or certificate files.
    • If you attempt to download a new installer from the VidyoPortal™ but there is not enough room in the write cache, the VidyoRoom will not download the installer. Instead, it will continue to check the cache every three hours, and it will download the installer when there is enough room.
  • New Admin UI settings
    • Concerned that displaying the VidyoPortal URL, user name, or password on the VidyoRoom OnScreen UI could be security risk? If so, we’ve added a setting to the Admin UI that prevents these from appearing on the OnScreen UI.
    • The new Network Tools tab on the Admin UI provides you with easy access to the “ping” and “traceroute” commands. You simply enter the IP address or host name of the system that you want to ping or trace the path of, and the results appear on the page.
    • From one page on the Admin UI, you can now conveniently set the system time manually or you can automatically sync the time with an NTP server.
    • If you have a Sony® camera and you have set up its presets, you can now indicate that you want the camera position to remain unchanged at the end of each call.
  • Remote Control API updates
    • The new Request Join Extension API enables you to join scheduled rooms using the room extension. This API works with scheduled rooms only and not with personal or public rooms.
    • Remote Control API commands now work with rooms and usernames that have a period in the name as long as the parameter is within single quotes. For example, here’s how you can now query the lock status of a room called qa.test: request status room.’qa.test’.locked.
    • The new RemoteShareAdded, RemoteShareRemoved, and ActiveRemoteShareChanged APIs enable you to tell if a remote participant is sharing content into the conference and if the other participants are currently viewing that content.
  • Support for the Biamp® TesiraFORTÉ CI audio device
    • The Biamp TesiraFORTÉ CI is an external codec conferencing solution that offers twelve line level inputs with AEC and eight line level outputs, thereby delivering superior audio conferencing.

Compatibility

To determine which version of the VidyoPortal™ your VidyoRoom™ or your VidyoPanorama™ 600 is compatible with, do one of the following:

Version 3.3.20 (0698) of the VidyoRoom client is compatible with the following Vidyo images:

 

VidyoRoom Family Vidyo Image
HD-2 HD2-Win64-0_2_20_0_0584.vimage
HD-3 HD3-Win64-0_2_21_0_0572.vimage
HD-40 Revision A HD40-Win32-0_0_1_15_0084.vimage
HD40-Win32-0_0_1_16_0126.vimage
HD40-Win32-0_0_1_17_0270.vimage
HD40-Win32-0_1_21_8-0676.vimage
HD-40 Revision B HD40B-Win64-0_0_2_9_0094.vimage
HD40B-Win64-0_0_2_12_0126.vimage
HD40B-Win64-0_0_2_15_0139.vimage
HD40B-Win64-0_2_17_0_0295.vimage
HD-40 Revision C HD40C-Win64-0_2_24_0_0510.vimage
HD-100 Revision D HD100D-Win64-0_0_2_8_0086.vimage
HD100D-Win64-0_0_2_10_0120.vimage
HD100D-Win64-0_0_2_15_0139.vimage
HD100D-Win64-0_2_17_0_0295.vimage
HD-230 Revision A HD230-Win64-0_0_2_8_0101.vimage
HD230-Win64-0_0_2_10_0120.vimage
HD230-Win64-0_0_2_15_0139.vimage
HD230A-Win64-0_2_20_0_0510.vimage
HD-230 Revision B HD230B-Win64-0_2_19_0_0295.vimage
HD230B-Win64-0_2_21_0_0295.vimage
VidyoPanorama 600 VP600-Win64-0_0_2_9_0101.vimage
VP600-Win64-0_0_2_11_0120.vimage
VP600-Win64-0_0_2_13_0139.vimage
VP600-Win64-0_2_14_0_0295.vimage

 

Vidyo highly recommends that you apply the latest available image when upgrading your VidyoRoom or VidyoPanorama 600. However, before uploading a new image, please check which image version your VidyoRoom system is currently running. If it is already running a newer image, do not downgrade to an older image.

 

VidyoPanorama 600 Internet Browser Compatibility: When viewing the Admin UI pages, you must use Internet Explorer® version 9 or later, Google® Chrome™ version 35 or later, Mozilla® Firefox® version 30 or later, or Apple® Safari® version 7 or later.

Resolved and Known Issues

Resolved Issues

The following table lists the resolved issues in VidyoRoom™ and VidyoPanorama™ 600 version 3.3.20 (0698):

VidyoRoom and VidyoPanorama Version 3.3.20 - Resolved Issues
Key Summary
GS-3707 and
VRMT-719
If a user connects and disconnects to a conference two or three times using the VidyoRemote 3, the VidyoRemote now continues to successfully communicate with the VidyoRoom and the search bar no longer remains in a busy state.

GS-3711 and
GS-3703

To prevent VidyoRoom systems from becoming unresponsive when trying to write an emergency commit, the write cache has been increased, the log file size has been reduced, and an emergency commit is triggered when less than 20% of the cache is free.
GS-3496 You can now determine if a remote participant is sharing content into the conference and if the other participants are currently viewing that content by using the new RemoteShareAdded, RemoteShareRemoved, and ActiveRemoteShareChanged APIs.
GS-3254 The issue that occasionally caused some VidyoRoom accounts to get locked out has been resolved.
GS-3242 VidyoRoom systems can now read the Phoenix Quattro3 firmware version if the Quattro3 is connected to the VidyoRoom system via a Phoenix power hub.
GS-3040 and
GS-3018
VidyoRoom systems no longer repeatedly attempt to download installers from the VidyoPortal™.
GS-2987 After the first login, VidyoRoom systems no longer use the username and password as credentials, but instead use the authentication token that is retrieved from the VidyoPortal.
GS-2875 The Swap Screen button now swaps screens when the VidyoRoom system uses two screens, and does not swap if there is one screen or more than two screens.
GS-2836 1080I resolution negotiation for INOGENI devices (when used as a camera source) has been implemented for Gen 3 VidyoRoom models such as the HD-2, HD-3, and HD-230.
GS-2608 Remote Control API commands now work with rooms and usernames that have a dot in the name as long as the parameter is within single quotes.

 

Known Issues

The following table lists the known issues in VidyoRoom™ and VidyoPanorama™ 600 version 3.3.20 (0676).

If a VidyoRoom or VidyoPanorama 600 upgrade is interrupted by a system reboot or by cutting the power supply, the system may no longer boot properly, the device selection may be incorrect, and other issues may occur. If this happens, you may have to recover the system via the Recovery Console.

 

VidyoRoom and VidyoPanorama Version 3.3.20 - Known Issues
Key Summary
VidyoRemote™ 3
GS-2874 When a user presses the numbers on the dial pad to send DTMF tones, there is an audio indication, but no indication on the UI.
GS-2510 When using the VidyoRemote 3, users cannot join a scheduled room by entering the full extension in the Search field.
GS-2397 If the background image is changed on the On-Screen UI Settings page, it does not get changed on the VidyoRemote 3 Settings page.
GS-2386 If a user is changed from the presenter to a viewer, the “Raise Hand” icon on that user’s VidyoRemote 3 disappears from the UI.
GS-2085 When a Revolabs UC-500 or UC-1000 audio device is connected to a VidyoRoom SE on a Mac®, changing the audio from the VidyoRemote 3 has no effect on the audio from the Revolabs device.
GS-2081 Once the VidyoRoom is controlled by the VidyoRemote 3 (that is, once the pair is established), the display name which is displayed on the top left corner of the On-Screen UI changes to user name.
GS-2027 When using VidyoRemote 3 and entering credentials for a Mac OS X user, VidyoRoom SE cannot be selected as the room system and the error message “Could not connect to the room system. Please check your room IP address and your network connection” appears.
GS-1843 When using the VidyoRemote 3, if a user removes their self-view, local projection gets disabled as well.
GS-1842 The VidyoRemote 3 does not have the DTMF function.
GS-1738

On a single display VidyoRoom using the VidyoRemote 3, the self-view preview and local projection get out of sync after disconnecting from the call. 

Workaround: Click the self-view preview and local projection icons two times to get them back in sync.
GS-1442 If a user is performing PTZ operations with the VidyoRemote 3 application and network connection problems occur between the VidyoRemote 3 and the VidyoRoom, the two may become out of sync. This results in the VidyoRemote 3 showing its home screen while the VidyoRoom screen shows the PTZ controls for the participant whose camera was being controlled when the network disconnection occurred.
GS-1409 It is not possible to PTZ cameras of guest participants from the VidyoRemote 3.
GS-1298 If a user with VidyoRemote 3 joins a call and is displaying local content, and then another participant in the call starts to share content and then stops, the VidyoRemote 3 user’s local content does not reappear automatically.
GS-1256 The Backlight On/Off option for the VidyoRemote 3 is not synced with the Admin UI Backlight On/Off option.
GS-1254

When using VidyoRemote, a user can change his/her VidyoPortal™ credentials during a call. 

Workaround: On the Admin UI Settings page, set an access code using the “Enable Settings Access Code” checkbox to prevent users from changing the credentials.
GS-960 If a user with VidyoRemote 3 clicks the Raise Hand button and their Raise Hand request is dismissed by the presenter, the button remains unchanged; therefore, the user doesn’t know that the request got dismissed, and additionally, that user must cancel the first request if they want to send a new Raise Hand request.
All VidyoRoom Models Unless Otherwise Specified
GS-3580 If the NTP Server checkbox is selected and the Apply button is clicked, it may occasionally take up to 15 seconds for the NTP service to be enabled, during which time the message “loading…” displays.
GS-3546 For proper calendar integration, the user should ensure that both the time zone and time on the system are correct; changing the time or time zone after calendar integration could cause the user to miss some meetings invitations.
GS-3501 If the network connection was lost while an image was being uploaded, the VidyoRoom system must be rebooted in order to upload the new image again; otherwise, the Admin UI will indicate that there is not enough space to upload the new image.
GS-3478 When two VidyoRoom systems log in to the VidyoPortal with the same credentials, the resulting behavior is not consistent (for example, one VidyoRoom may remain online while the other keeps trying to log in).
GS-3361 When a Sony EVI-H100V camera is set to D70 mode, the On-Screen UI and Admin UI About page display the camera model as D70.
GS-3360 When a camera has a long model name, such as the Sony EVI-HD7V and Sony SRG-120DH, the name wraps around to a second line on the Admin UI About page.
GS-3354 The format of the Minrray camera version that displays on the On-Screen UI and on the Admin UI About page is not the same format used by Minrray (for example, if the Minrray version is 2.2.3, the VidyoRoom could display 22.30).
GS-3342

When a content sharing device is connected and the user is on the Home screen of the On-Screen UI, if the user presses the Self-view key, the self-view tile will not toggle off.

Workaround: Press the Manage key from the Home screen or disconnect the content sharing device and then reconnect it.
GS-3336

If a user swaps displays by pressing the A button on the remote control and one of the displays is disconnected, the user may not be able to see the remote participants.

Workaround: If this issue occurs, reboot the system to see the remote participants’ tiles. To prevent this issue, before removing a display, use the A button on the remote to swap the displays, and then either physically swap the display connections or use the Admin UI to swap the settings for each display.
GS-3330 Occasionally, when the Start Recording request is sent when the VidyoRoom system is not in a call, it causes the VidyoRoom system to crash.
GS-3282
and
GS-3281

If a VidyoRoom upgrade is interrupted by a system reboot or by cutting the power supply, the system may no longer boot properly, the device selection may be incorrect, and other issues may occur.

Workaround: Do not power off the system during an upgrade. However, if this inadvertently occurs, you may have to recover the system via the Recovery Console.
GS-3260 Log files cannot be downloaded successfully if the total size is bigger than 2GB.
GS-3256 Under high temperature conditions, VidyoRoom response time slows down and the systems take longer to get fully operational after being rebooted.
GS-3245

VidyoRoom does not limit the caption length; instead, as the caption gets longer, the point size of the font decreases.

Workaround: The moderator client should limit the length of the caption to 80 characters for languages that use the English alphabet and 34 characters for Chinese and other Asian languages.
GS-3230 When in a call using a VidyoRoom with two displays, if the user changes which display is the Primary display via the Admin UI Display Layout page, the participant number and its corresponding green icon will appear on separate displays.
GS-3210 When using a VidyoRoom system with two displays, if the settings of the displays are different (for instance, one of them is for displaying content only or the number of tiles to be displayed are different), if the displays are swapped by pressing the A button on the remote control after joining a conference, the participants may no longer display correctly.
GS-3145 The “Call in progress” indication does not display if a user shares content after toggling their local projection.
GS-3102 The “Call in progress” indication does not display when a VidyoRoom with multiple screens has only the user’s self-view displayed.
GS-3097 The “Call in progress” indication does not display when Presenter mode is enabled but a presenter has not been selected or has left the conference.
GS-3089 The Splunk® forwarder is unable to pass VidyoRoom crash dumps and BSODs to the server.
GS-2927
and
GS-2256

When setting a Sony SRG-300H camera or a Sony SRG-120DH camera to VISCA, the camera resolution cannot be changed from the VidyoRoom’s configuration and remains set to 1080p60.

Workaround: Set the camera manually to the mode you want to use.
GS-2919

If a UniBrain USB 3.0 Active Optical Cable is unplugged from either the VidyoRoom system or from the host device linking the cable and USB 3.0 camera cable, after the UniBrain cable is plugged back in, the camera is not detected. 

Workaround: In order for the camera you get detected, power cycle the UniBrain device.

GS-2852 In very rare cases, an ungraceful shutdown of a VidyoRoom connected to a power hub with a Phoenix Spider MT503 could cause the power hub to stop working.
GS-2815 If a VidyoRoom unit is connected to a power hub with a Phoenix Spider MT503, all HID-related functions (such as mute, volume, connect, etc.) do not work.
GS-2734 When Minrray® UV950A camera is connected to a VidyoRoom running version 2.x, the Anti-Flicker setting cannot be synchronized to the camera.
GS-2719 Some USB devices, such as the Phoenix Spider and the Logitech® GROUP, are not detected when connected with APC USB extenders.
GS-2709 The Mic buttons on the Phoenix Spider are not integrated with the VidyoRoom; therefore, pressing those buttons on the Spider has no effect on the VidyoRoom microphone volume.
GS-2705 The Admin UI does not notify the user that the “Enable/Disable Remote Control Interface” checkbox requires a reboot.
GS-2655

When a Revolabs FLX™ UC 1000 device is power cycled, by default it powers up with the USB set to “Off”; therefore, there is no audio from the device.

Workaround: On the FLX UC 1000 dial pad, go to Menu > Settings > Admin Settings > Enter password (default is 7386) > USB Settings and select “Always Enabled”.
GS-2606 VidyoRoom cannot download the client from the VidyoPortal when web proxy and VidyoProxy are enabled, and the “File download request failed with result code 408” appears in the log.
GS-2548 If a Logitech GROUP or CC3000e is connected to a VidyoRoom after a call has been joined, and then the user presses the Mute button, the call gets disconnected.
GS-2403 If a user toggles their own local projection before any remote participant starts to share content, and then a remote participant shares content and the user toggles that content, the content reduces to a participant tile.
GS-2399 The VidyoRoom does not maintain the selected display mode for local projection; instead, local projection always appears after remote content sharing is stopped.
GS-2396 If a user shares content and the shared content goes to sleep before the user stops sharing it, when the user wakes it up, the shared content will not appear in full screen.
GS-2363 PTZ stops working when both a Logitech CC3000e and a C910 are connected to a VidyoRoom.
GS-2350 In some cases, the VidyoPanorama 600 is unable to negotiate proper resolutions after being powered off and powered back on.
GS-2324 If a single-display VidyoRoom is being used in Local Projection mode (where the user sees the content locally connected) and the sleep timeout limit is reached, the VidyoRoom system goes into Sleep mode.
GS-2316 When the VidyoRoom is in Presenter mode, conference messages do not appear when the On-Screen UI is disabled.
GS-2270 The Static IP configuration cannot be saved if the network cable is not connected.
GS-2252 When connected to the VidyoRoom via the Extron or Xtendez extenders, the Sony SRG-120DH camera resets to the default position after system reboot.
GS-2194

If a user makes configuration changes and also switches from normal mode to side-by-side mode, clicks Apply to apply the changes, and then clicks Cancel on the Reboot Required pop-up, some of the changes are canceled but some of them are applied.

Workaround: Reboot the system to apply all the changes.
GS-2157 When the Anti-Flicker Mode setting in the Video section of the Admin UI > Settings page is changed, the Save button must be pressed in order to save the change.
GS-2147

Changing resolution from 720p to 1080p via VISCA when using Sony cameras results in distorted video.

Workaround: Reboot the camera.
GS-1924

Occasionally, an INOGENI device does not recover during an installer upgrade.

Workaround: When an INOGENI device fails to recover after an upgrade, power down the VidyoRoom system and wait at least 30 seconds before powering it back up. When the VidyoRoom powers back up, the INOGENI device will be upgraded.
GS-1923 If a new audio or video device is plugged into the VidyoRoom when the VidyoRoom is powered off, the device does not get automatically selected as a new device when the VidyoRoom is powered back on.
GS-1910 VidyoPanorama 600 and VidyoRoom appear as “VidyoPanoroom” in the CDR instead of “VidyoPanorama”.
GS-1882 If a USB device is selected as the sharing source and is then unplugged, the On-Screen UI does not show the device as disconnected, but continues to show the device as the selected sharing source. This occurs only when using a VidyoRoom with only one available sharing source.
GS-1855 When the PT Inquiry command to a Sony camera returns an error, the PT Reset command is not executed.
GS-1840 When a user in a Vidyo conference invites another user to join the conference, the inviting user receives no indication (visible, audible, or tactile) that the invitation was sent.
GS-1787 In rare cases, the On-Screen UI does not respond to any button presses except for the Manage and Self-view buttons.
GS-1782

In certain scenarios when in a conference (usually with a VidyoPanorama 600), the Home page is displayed on the screen instead of the Manage page when the Manage button is pressed on the remote control. 

Workaround: Rejoin the conference or press the Settings button and then input a correct FAC.
GS-1757 On some occasions, the recovery to the enhanced layer does not work immediately after some remote users leave the call. It may take up to ten minutes to recover the enhanced layer.
GS-1719

Occasionally on VidyoRoom systems with two different displays (one 720p and one 1080p), the On-Screen UI may use an incorrect resolution if one of the displays loses power and then re-gains it.

Workaround: Reboot the VidyoRoom system or press the A button on the radio frequency remote twice to swap the displays.
GS-1715

When content capture mode is set to 720P but the display resolution for connected 4K INOGENI devices is set higher than 720P, the application will overscan, which may result in cropped edges on the captured image.

Workaround: Ensure that the display resolution for 4K INOGENI devices is set to 720P.
GS-1694 If a user joins a conference after more than one content share has been shared with the other participants, the user may not see the same content share as the other participants.
GS-1680 If the Use Status IPv6 checkbox is selected in the Admin UI, you cannot select or deselect the Enable IPv6 checkbox.
GS-1628 The Microsoft Office 365® calendar does not get configured when the Microsoft Exchange Server Web Service URL is set to “Auto Discover”.
GS-1603 When using a Sony EVI-H100V camera, issues occur when downscaling from 1080p to 720p. For example, colors may appear washed out, text looks blurry when zoomed all the way in, and the camera focuses longer with 1080p than with 720p.
GS-1544 When using the On-Screen UI to change the VidyoProxy setting, the change does not take effect until you reboot your VidyoRoom.
GS-1526

Occasionally, when upgrading a VidyoRoom from version 2.2.6 to 2.2.8 or from 2.2.4 to 2.2.6, the upgrade fails and a message displays stating “Please restart the VidyoRoom system.”

Workaround: Restart the VidyoRoom and perform the upgrade again.
GS-1507 If a call was joined using a calendar invitation, the username that the remote API replies with is not correct.
GS-1494

The screen saver gets activated when the VidyoRoom system upgrades a connected peripheral. 

Workaround: Although the screen saver appears, the upgrade continues to proceed as normal.
GS-1458 VidyoRoom is unable to join a scheduled room when simultaneously dialing an extension.
GS-1451 There is no On-Screen UI indication that lets users know if Fn lock has been activated.
GS-1427 When a Logitech ConferenceCam Connect is used, mute is not synchronized between the VidyoRoom and the Logitech.
GS-1407 If an invalid time server is configured in the Admin UI, the PC will be unable to sync time with the external time server and the local CMOS clock will be used as a time source (as expected); however, the user is not notified of the sync failure.
GS-1404 If the time server in the Admin UI is set to a time other than the default and then the system is restored to the factory defaults of an Anchor release, when the system is upgraded again using the installer, the time server is not set back to the user’s preference.
GS-1403 When the volume up and down is changed on a Revolabs FLX UC500, the speaker bar on the VidyoRoom On-Screen UI does not change accordingly.
GS-1395 Occasionally, some VidyoRoom systems stop encoding when content sharing from an INOGENI device is stopped. This is not applicable to the VidyoPanorama 600, which does not support INOGENI devices.
GS-1363 When the frame rate on VidyoRoom systems with more than one display (such as the HD-230 and the VidyoPanorama 600) is set for 30 fps or 15 fps, the self-view occasionally displays at half the configured frame rate.
GS-1359 When mute is turned on or off on a Yamaha® YVC audio device, the mute indicator on the VidyoRoom On-Screen UI does not change accordingly.
GS-1355 The resolution on an AMC-K2001 camera cannot be changed over VISCA.
GS-1259 When the VidyoRoom video transmit rate is set to 360p at 384 Kb/s, it impacts the receive bit rate of its clients in that the receive video remains at a low bit rate.
GS-1247 When a new moderator controls the meeting after a presenter shared to the conference while using Presenter mode, the original shared content incorrectly remains shared.
GS-1223

If a call is dropped or a user disconnects from a conference while the speakers are turned off, the next incoming calls appear as messages on the display but they do not ring.

Workaround: Answer one of the incoming calls and then disconnect while the speakers are on; subsequent incoming calls will then ring.
GS-1135 The VidyoRoom control interface is only available in the English language. If the On-Screen UI is set to another language, the control interface continues to display in English.
GS-1042 When the DNS resolution fails because the user has the wrong DNS name, the user is not able to log in, but is not notified with a reason.
GS-853

When a VidyoPanorama 600 system is configured with only one display, the Manage key on the infrared remote control must be pressed three or four times in order to first access the In-Call menu while in a call.

Workaround: After accessing the In-Call menu for the first time during a call, the menu can be accessed subsequently with just one press of the Manage key.
GS-835 The process of updating an INOGENI device takes several minutes, during which the screensaver typically displays. The screensaver is not an indication that the upgrade has paused or finished; therefore, users should not disturb the system and should allow the upgrade to complete.
GS-455 Remote users see a black, green, and gray window if a camera is not connected on VidyoInput1, VidyoInput2, or INOGENI video sources.
VidyoRoom HD-2 Only
GSI-103 It can take up to one minute to copy the image key label information to an HD-2 system.
GS-3113 Occasionally, the Minrray UV950A camera continues to move after the user stops pressing the PTZ button.
GS-2916

When using a 4K display with an HD-2, a No Signal message appears when the resolution is changed from 4K@30 to 1080p60.

Workaround: If you have a 4K display set at 4K@30 and want to change to 1080p60, you must first change the resolution to 1080p30 and then change it to 1080p60. Note that some displays, such as Vizio 4K displays, do not support 1080p30, so you may see blurry video when you select 1080p30.
GS-2913 When using a Minrray UV950A camera with an HD-2 at 1080p60@4M or 6M resolution, the Captured/Encoded framerate drops when a content share device is selected (whether or not content is actually shared).
VidyoRoom HD-3 Only
GSB-4

If a VidyoRoom HD-3 is powered off ungracefully and then a user powers it back on using the Power button, the HD-3 powers on for a few seconds and then powers off automatically.

Workaround: Press the Power button again to properly power on the HD-3.
GSI-99

On rare occasions, a blank screen may appear when you access the Recovery Console.

Workaround: Press the Power button to shut down the system, and then re-enter the Recovery Console.
GSI-55 After imaging a VidyoRoom HD-3, the AutoShare Connected Device setting gets set to Off.
GSI-54 After imaging a VidyoRoom HD-3, the Anti-Flicker setting gets set to “Off”.
GSI-51 In four-display setups of the VidyoRoom HD-3 with all displays configured to 1080p, 1080p30 video encode, and 4x1080p60 decodes with one tile sharing content at 1080p, the rendered FPS drops to the 50s.
GS-2935 The ambiguous message “Installer file is invalid” appears when an unsupported installer version is uploaded.
GS-2845 In some cases, if a Revolabs line-in/line-out audio device is disconnected and then reconnected to a VidyoRoom HD-3, it may cause the HD-3 to crash.
GS-2844 In two-display setups of the VidyoRoom HD-3 with both displays configured to decode in 4K resolution, no more than eight participants can be displayed per screen. Even if the user sets the Admin UI to display more, the system will limit the number of participants displayed on each screen to eight.
GS-2822

If a VidyoRoom HD-3 is shut down while an image upgrade is in progress, the HD-3 gets stuck in a BSOD loop.

Workaround: Reboot into the Recovery Console and perform a Factory Restore.
GS-2776 In four-display setups of the VidyoRoom HD-3, in rare conditions, the Render Rate of the 1080p60 displays does not remain stable and occasionally drops to the 50s.
GS-2681 In two-display setups of the VidyoRoom HD-3 with both displays configured to 1080p60, if one display is unplugged, the remaining displays convert to 4K.
GS-2663

In four-display setups of the VidyoRoom HD-3, clicking the “Unlock EDIDs” button causes the displays to randomly disappear from the Admin UI display layout and causes their resolutions to change in the Admin UI. 

Workaround: Click the “Lock EDIDs” button after configuring the display layout—especially when using 4K monitors. If you need to unplug a display, you must click “Unlock EDIDs”, change the display setup, reboot, configure the displays, and then click “Lock EDIDs”. For more information, refer to the VidyoRoom and VidyoPanorama 600 Administrator Guide.
GS-2583

In two-display setups of the VidyoRoom HD-3 with both displays configured to 4k, the displays boot up with black screens after the VidyoRoom is keyed.

Workaround: On the Display Layout tab in the Admin UI, change the resolution to the correct resolution for the display.
GS-2566 Extron extenders are unstable in two-display setups of the VidyoRoom HD-3 with both displays configured to 4k.
GS-2523 When 720p15 and 1080p15 are selected for the camera connected to an HD-3, the statistics display 30 fps.
GS-2495 In a setup of the VidyoRoom HD-3 with more than two displays, when a remote participant shares content and then stops sharing, the display layout may change.
VidyoRoom HD-40 Only
GS-3337

An exception error can occur if the VidyoRoom receives numerous IPv6 temporary addresses.

Workaround: Deselect the Enable IPv6 checkbox if your VidyoPortal does not support IPv6.
GS-2996 If no content is being shared and the “Preview Local Content” checkbox is not selected in the Admin UI, and then the user selects the “Preview Local Content” checkbox , a green screen appears.
GS-2955 If a Sony SRG-300H camera is connected to a VidyoRoom HD-40 Revision A or Revision C via an extender, the camera does not go to its previous position after the VidyoRoom system is rebooted.
GS-2954

In some cases, if a Sony EVI-H100V camera is connected to a VidyoRoom HD-40 Revision A with StarTech extenders, when a power outage occurs, the Sony camera freezes.

Workaround: In order for the camera to get detected, while still in the call, deselect and then re-select the camera from the Admin UI.
GS-2941

If a Sony SRG camera is connected to a VidyoRoom HD-40 Revision C with a UniBrain extender when a power outage occurs, the Sony camera freezes. 

Workaround: In order for the camera to get detected, while still in the call, deselect and then re-select the camera from the Admin UI.
GS-2269 If a user has multiple audio devices plugged in and the selected audio device is unplugged after a system shutdown, then television speakers are automatically selected for the audio output.
GS-1922 If a VidyoRoom HD-40 Revision A system is ungracefully shutdown (such as during a power outage), in rare instances, the INOGENI device will not get detected by the VidyoRoom until the next time the VidyoRoom is rebooted.
GS-1795 A VidyoRoom HD-40 Revision A with a Sony EVI-H100V and an INOGENI device occasionally crashes if the television display is turned off while the VidyoRoom system is operational upon joining and leaving calls, and when camera control is in progress.
GS-1790 The Google calendar account is not a supported feature with VidyoRoom HD-40 Revision A. An invalid username/password error message displays when the correct credentials have been entered.
GS-1737 If a VidyoRoom HD-40 Revision A is connected to non-Vidyo branded INOGENI devices, the non-branded INOGENI firmware does not get updated when upgrading from VidyoRoom version 3.2.4 to version 3.3.5.
GS-1631

Occasionally, soft-bricked INOGENI devices cannot be recovered after rebooting.

Workaround:
1. Power off the VidyoRoom HD-40 Rev A system.
2. Wait 30 seconds.
3. Power the HD-40 Rev A back on.
GS-1003 The self-view sporadically displays with an approximate 700 ms of latency in conferences.
VidyoRoom HD-100 Revision 4A Only
GSI-138 VidyoRoom HD-100 Revision 4A systems go into sleep mode while the system is being configured after an image upgrade.
GSI-130

When certain keyboards are connected to the rear USB ports on VidyoRoom HD-100 Revision 4A systems, it may take the Recovery Console up to 17 seconds to appear after the Recovery Console option is selected.

Workaround: If you experience this issue, use the front USB ports to connect your keyboard.
GS-3554

In roughly one of 600 attempts, VidyoRoom HD-100 Revision 4A systems experienced a BSOD error upon rebooting and/or after an ungraceful shutdown.

Workaround: Press and hold the Power button to shut off the system, and then press the Power button again to power it back on.

GS-3497 and
GS-3248

In roughly one of 600 attempts, VidyoRoom HD-100 Revision 4A systems experienced a BSOD and displayed a boot device error upon rebooting and/or after an ungraceful shutdown.

Workaround: Press and hold the Power button to shut off the system, and then press the Power button again to power it back on.

GS-3401

eLert devices do not work when connected to the front USB ports on VidyoRoom HD-100 Revision 4A systems.

Workaround: Use the rear USB ports to connect eLert devices.
GS-3275

Under high temperature conditions, if a tvONE video scaler is connected to a VidyoRoom HD-100 Revision 4A system, the tvONE scaler may reset to factory defaults which would result in the remote site seeing green or black video.

Workaround: If this issue occurs, manually reset the correct resolution on the tvONE scaler.
GS-3257 Under high temperature conditions, the cameras on VidyoRoom HD-100 Revision 4A systems stop capturing frames and the green icon (which normally displays alongside the participant number) appears on the remote site.
GS-2924 If a VidyoRoom HD-100 Revision 4A is re-imaged with a Gen 3 VidyoRoom image, the microphone and speaker volume settings are not maintained.
GS-2238

If there is an active 32-bit VidyoRoom installer on the VidyoPortal that is older than version 3.3.8.0505 and that installer is applied to any VidyoRoom HD-100 Revision 4A system running VidyoRoom version 3.3.x, the VidyoRoom HD-100 Revision 4A systems become inoperable.

Workaround: Ensure that there are no active 32-bit VidyoRoom installer versions older than 3.3.8.0505 on the VidyoPortal prior to upgrading to VidyoRoom version 3.3.8. If you inadvertently downgrade to an older version on a VidyoRoom HD-100 Revision 4A system, you will need to re-image it from the Recovery Console.
GS-2202

The Restore to Factory Image fails when users click the Restore Factory Image button on the Admin UI when all image files are deleted.

Workaround: Reboot locally and upload the image that needs to be applied in the Admin UI or upload the image from the USB drive via the recovery console.
GS-1972 The camera on VidyoRoom HD-100 Revision 4A systems cannot be powered off. If the camera is manually powered off, the VidyoRoom HD-100 Revision 4A resets the camera and powers it on again.
GS-1784 In rare cases, when a VidyoRoom HD-100 Revision D runs for a long period of time (such as overnight), it may display a blue self-view screen; if so, the other participants in the conference will also see a blue screen instead of video from that VidyoRoom.
GS-1720 On VidyoRoom HD-100 Revision 4A systems, a stop error code message displays during system reboots.
GS-1712 When a Sony D70 camera is connected to an HD-100 Revision 4A, the camera may not come back to its configured position after the VidyoRoom system is rebooted.
GS-1602 After re-imaging a VidyoRoom HD-100 Revision 4A system, eLERT devices are not recognized if they are connected to a USB port on the front of the VidyoRoom system.
GS-1574 If a VidyoRoom HD-100 Revision 4A is re-imaged with a Gen 3 VidyoRoom image, the microphone and speaker volume settings are not maintained.
GS-1422 Occasionally, in very long calls (such as a call that lasts overnight), participants in the conference see frozen video from an HD-100 Revision 4A. 
Workaround: Disconnect and then re-join the conference.
GS-1324 Unlike other VidyoRoom models, it may take up to ten minutes to upgrade an HD-100 Revision 4A.
GS-1316 If two monitors are connected to an HD-100 Revision 4A and the main display is configured for four tiles, the HD-100 restarts if it joins a conference with more than four participants.
VidyoRoom HD-230 Only
GS-2302 If the active camera is disconnected from a VidyoRoom HD-230, Vidyo Input 1 or Vidyo Input 2 automatically gets selected as the content share device.
GS-2297 If a user of a VidyoRoom HD-230 changes the resolution of a Sony SRG USB camera, that user then has to manually re-select the Sony as the camera device.
GS-2283 The HD-230A and HD-230 images can be uploaded to the VidyoRoom HD-230 system via the Recovery Console.
GS-2231 The Sony SRG USB 3.0 camera does not display 1080p when connected to a VidyoRoom HD-230 system. When configuring 1080p from the On Screen UI, the self-view does not display and the screen is black.
GS-2228 If the VidyoRoom HD-230 system is unexpectedly shutdown (e.g., power outage), then the connected camera may not be detected by the room system until after rebooting.
GS-1722 For VidyoRoom HD-230 and VidyoPanorama 600 systems, Vidyo Input 2 is selected automatically as the new sharing source; however, if you then click the Enable/Disable Local Preview button on the top-right of the Home screen, a green screen displays.
VidyoRoom SE Only
GS-2504 When a Sony® SRG-120 camera is being used with a VidyoRoom SE, the resolution on the camera cannot be changed to 1080p15.
GS-2499 Occasionally, when using a VidyoRoom SE, the Sony SRG-120 camera stops appearing in the list of cameras after the resolution is changed.
GS-2408 While in a call with a VidyoRoom SE and a Logitech GROUP, if the camera is deselected and then reselected, it appears as a green screen for remote participants as well as in the self-view.
GS-2354 In order for an INOGENI device to work with VidyoRoom SE, the latest chipset drivers, USB 3.0 drivers, and INOGENI drivers must be installed.
GS-2207

If the SystemManufacturer or the SystemProductName are not set properly on the machine, users will not be able to log in to VidyoRoom SE.

Workaround: Set SystemManufacturer and SystemProductName to valid strings.
GS-2185

After switching from side-by-side mode back to regular mode and restarting the system, a Windows® 10 upgrade notification message appears on top of the self-view and local projection. 

Workaround: Because the cursor is disabled in regular mode, you must exit the VidyoRoom SE application to close the notification.
GS-2142

Occasionally, when a user launches an app, the app can be opened on the monitor which is already being used by VidyoRoom SE. 

Workaround: Drag the app window to the other monitor to prevent it from blocking VidyoRoom SE.
GS-2014 The in-call icons that appear to VidyoRoom SE users (such as the microphone and speaker icons) are smaller than typical VidyoRoom icons.
GS-1962 The option to change the VidyoRoom SE IP address is available on the Admin UI even though the VidyoRoom SE always inherits the computer’s IP address. If a user attempts to change the IP address via the Admin UI, the VidyoRoom SE will not save the changes.
GS-1498 If VidyoRoom SE is running on a Windows computer where Windows UAC is not disabled, and the user starts an upgrade but takes an hour or longer to respond to the Windows UAC pop-up that asks “Do you want to allow the following program from an Unknown publisher to make changes…”, the VidyoRoom application stops running.

 

Was this article helpful?